INSTALLATION & OPERATION
MANUAL
SP2850 (MS-649)
Temperature Compensated
2 Stage Batch Controller
DOC#: MN-2850
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - INSTALLATION & OPERATION

INSTALLATION & OPERATION MANUAL SP2850 (MS-649) Temperature Compensated 2 Stage Batch Controller DOC#: MN-2850

Page 2 - INTRODUCTION

Sponsler, Inc. Model SP2850-TC with MS649 Page 10 DOC#: MN-2850 DEFINITION OF MENU PROMPTS MENU- This prompt is displayed when the programming me

Page 3

Sponsler, Inc. Model SP2850-TC with MS649 Page 11 DOC#: MN-2850 DEC LOC- (DECIMAL LOCATION); This sets the decimal location for the counter, preset

Page 4

Sponsler, Inc. Model SP2850-TC with MS649 Page 12 DOC#: MN-2850 4-20mA- This sets the compensation input for 4-20mA input when selected and jumper

Page 5

Sponsler, Inc. Model SP2850-TC with MS649 Page 13 DOC#: MN-2850 ERROR MESSAGES While programming and running the unit, various error messages may b

Page 6 - INSTALLATION

Sponsler, Inc. Model SP2850-TC with MS649 Page 14 DOC#: MN-2850 PROGRAMMING FLOWCHART * SECURIT

Page 7 - AC/DC Connections:

Sponsler, Inc. Model SP2850-TC with MS649 Page 15 DOC#: MN-2850 SETUP PROCEDURES NOTE: Start here and finish to the end. If you make a mistake, pr

Page 8

Sponsler, Inc. Model SP2850-TC with MS649 Page 16 DOC#: MN-2850 (Press D to display desired timebase) ENT (selects displayed options) K-FACTOR (

Page 9

Sponsler, Inc. Model SP2850-TC with MS649 Page 17 DOC#: MN-2850 16-POINT LINEARIZATION OPTION Description: The 16 point K-Factor option allows the

Page 10 - DEFINITION OF MENU PROMPTS

Sponsler, Inc. Model SP2850-TC with MS649 Page 18 DOC#: MN-2850 DATA ENTRY FOR 16-POINT Press `D’ until `16 POINT’ appears on display. Press `ENT

Page 11

Sponsler, Inc. Model SP2850-TC with MS649 Page 19 DOC#: MN-2850 SETUP PROCEDURES CONTINUED STEP 5: Setting the Counter Press Display D MENU Fla

Page 12

Sponsler, Inc. Model SP2850-TC with MS649 Page 2 DOC#: MN-2850 INTRODUCTION Featuring 8 digits of bright, .55”, alpha-numeric display, the unit

Page 13 - ERROR MESSAGES

Sponsler, Inc. Model SP2850-TC with MS649 Page 20 DOC#: MN-2850 CLR SIGFIG 00 6 Example Only. SIGFIG 06 Key in the desired number of digit

Page 14

Sponsler, Inc. Model SP2850-TC with MS649 Page 21 DOC#: MN-2850 D 600 ↓ D 1200 ↓ D 2400 ↓ D 4800 ↓ D 9600 ↓ (Press D to go t

Page 15 - SETUP PROCEDURES

Sponsler, Inc. Model SP2850-TC with MS649 Page 22 DOC#: MN-2850 ENT 20000 ↓ (Displays last selection) D 2000 ↓ D 200 ↓ D 10 ↓ (Pres

Page 16

Sponsler, Inc. Model SP2850-TC with MS649 Page 23 DOC#: MN-2850 D 4-20MA ↓ D 0-5V ↓ D 0-10V ↓ D MANUAL ↓ (Press D to go to RTD ↓)

Page 17

Sponsler, Inc. Model SP2850-TC with MS649 Page 24 DOC#: MN-2850 D MANUAL ↓ (Press D to go to RTD ↓) ENT (Selects displayed option) DN ↓ TEMP

Page 18

Sponsler, Inc. Model SP2850-TC with MS649 Page 25 DOC#: MN-2850 1 0 0 D 0 (As an example) 100.0 (Flashing) (Press D for decimal, press C to

Page 19 - SETUP PROCEDURES CONTINUED

Sponsler, Inc. Model SP2850-TC with MS649 Page 26 DOC#: MN-2850 CLR 0 (Flashing) 1 0 0 D 0 (As an example) 100.0 (Flashes) (Press D f

Page 20

Sponsler, Inc. Model SP2850-TC with MS649 Page 27 DOC#: MN-2850 TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSES SOLUTIONS Power is applied but the di

Page 21

Sponsler, Inc. Model SP2850-TC with MS649 Page 28 DOC#: MN-2850 CALCULATING EXPANSION COEFFICIENT Given: The liquid density is a function of the fl

Page 22

Sponsler, Inc. Model SP2850-TC with MS649 Page 29 DOC#: MN-2850 CALIBRATION NOTE: All units are calibrated and jumper options set for the requi

Page 23

Sponsler, Inc. Model SP2850-TC with MS649 Page 3 DOC#: MN-2850 RESET: Front push button: `CLEAR’ resets displayed batch counter and control input.

Page 24

Sponsler, Inc. Model SP2850-TC with MS649 Page 30 DOC#: MN-2850 JUMPER OPTIONS Jumper Connections Function Jumper Connections Function J1 J1 J2

Page 26

©2009 Pub. No. MN-2850-R1 (09/09)

Page 27

Sponsler, Inc. Model SP2850-TC with MS649 Page 4 DOC#: MN-2850 NOTE: Once the EZ PRE mode is entered, the internal LOCK is automatically turned on

Page 28

Sponsler, Inc. Model SP2850-TC with MS649 Page 5 DOC#: MN-2850 OPERATION: Through the 16 key, NEMA 4X/IP 65 front panel, the operator enters all th

Page 29

Sponsler, Inc. Model SP2850-TC with MS649 Page 6 DOC#: MN-2850 INSTALLATION Receipt of Equipment: When the equipment is received, the outside packi

Page 30

Sponsler, Inc. Model SP2850-TC with MS649 Page 7 DOC#: MN-2850 WIRING AC/DC Connections: NOTE: Connect power only after other connections are finis

Page 31

Sponsler, Inc. Model SP2850-TC with MS649 Page 8 DOC#: MN-2850 Typical Wiring: Pulse Input/RTD Input/Current Output Puls

Page 32 - Pub. No. MN-2850-R1

Sponsler, Inc. Model SP2850-TC with MS649 Page 9 DOC#: MN-2850 TYPICAL WIRING: SP714 & SP717 ANALOG OUTPUTS The o

Comments to this Manuals