Liquid-controls SP714-S2i User Manual

Browse online or download User Manual for Equipment Liquid-controls SP714-S2i. Liquid Controls SP714-S2i User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Liquid ControLs Group
An IDEX Fluid & Metering Business
Sponsler SP714-S2i
Pulse Amplier
Installation & Parts
Operation: EM700-10
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Sponsler SP714-S2i

Liquid ControLs GroupAn IDEX Fluid & Metering BusinessSponsler SP714-S2iPulse AmplierInstallation & PartsOperation: EM700-10

Page 2 - TABLE OF CONTENTS

The 3-wire Open Collector conguration translates the output signal from the turbine owmeter’s pickup coil into a voltage value.

Page 3 - ! WARNING

The R1 Input Signal Sensitivity Adjustment is a valuable tool that, in addition to SP714-S2i being directly mo

Page 4 - DIMENSIONS AND SPECIFICATIONS

© 2013 Liquid ControlsPub. No. 500372(8/2013)105 Albrecht DriveLake Bluff, IL 60044-22421.800.458.5262 • 847.295.1050Fax: 847.295.1057www.lcmeter.comT

Page 5 - SPECIFICATIONS

INTRODUCTIONSafety Procedures ... 3General Information ...

Page 6 - REGULATORY COMPLIANCE TAG

SAFETY PROCEDURES AND GENERAL INFORMATION! WARNINGNorth America - Installations must be in full accordance with the National Electrical Code (US) or t

Page 7 - INSTALLATION OVERVIEW

DIMENSIONS AND SPECIFICATIONSWeight• 1.2 lbs (0.54 kg)Materials of ConstructionHousing • Aluminum Alloy ADC12• Powder Coat: Corro-Coat PE 74-141 Polye

Page 8 - 2-WIRE STANDARD WIRING

SPECIFICATIONSMiniMuM MaxiMuM unitsDC power supply voltage: 12 VTotal System Resistance: 130 Ω ± 25 ΩOutpu

Page 9 - 

REGULATORY COMPLIANCE TAGExplosive Atmospheres symbolIECEX DNV 11.0012XThis equipment has been found to comply with the Certication Scheme for Explos

Page 10 - 

INSTALLATION OVERVIEWIn order to maintain IECEx compliance, the SP714-S2i is shipped as part of an assembly with a Sponsler turbi

Page 11 - SETTINGS & DIAGNOSTICS

2-WIRE STANDARDThe 2-wire Standard conguration translates the output signal from the turbine owmeter’s pickup coil into a current value. The 2-wire

Page 12

The 3-wire TTL Sourcing conguration translates the output signal from the turbine owmeter’s pickup coil into a voltage value. The

Comments to this Manuals

No comments